The furnace is running, but the air coming out is cold
Your furnace turns on, the fan blows — and cold air comes out of the vents. Sometimes the air starts warm and goes cold. Either way, the house isn’t heating, and it’s frustrating. The good news: the most common cause is a thermostat setting, and it takes ten seconds to check.
Call us at (616) 243-1914 if the checks below don’t fix it, or if the house is getting cold. We answer the phone 24 hours a day, 7 days a week. Regular service hours are Monday–Friday, 9 AM–5 PM, and 24/7 emergency service is available.
Check the fan setting first: AUTO, not ON
Look at your thermostat. There is a fan setting, usually marked AUTO and ON.
- AUTO means the fan runs only while the furnace is heating. This is the setting you want.
- ON means the fan runs all the time — even between heating cycles, when the furnace isn’t producing heat. The air coming out of the vents during those gaps is just room-temperature air being pushed around, and it feels cold.
If the fan is set to ON, switch it to AUTO and give the furnace a full heating cycle. This fixes the problem a surprising amount of the time.
Next: the filter and the registers
- Filter. A clogged filter chokes off airflow. The furnace can overheat and shut the burner off while the fan keeps running — so cold air blows through the vents. Pull the filter out and hold it up to a light. If you can’t see light through it, replace it with a new one of the same size.
- Registers. Make sure the vents (registers) in the rooms are open and not blocked by furniture, rugs, or curtains. Closed or blocked registers can throw off airflow and leave some rooms cold while others are fine.
Don’t keep resetting the furnace
If the furnace stops heating and you turn it off and on again to get it going, that may work once. Don’t keep doing it. Repeated resets can lock the furnace out — it stops trying entirely until a professional resets it — and they hide the real problem while it gets worse. If you’ve reset it twice and it still isn’t heating properly, leave it alone and call us.
What else could be wrong
If the fan setting, filter, and registers all check out, the problem is usually one of these:
- The burner never lights. The fan runs, but there’s no flame to heat the air. See Furnace Won’t Ignite? — the usual culprits are a dirty flame sensor or a worn igniter.
- Thermostat problem. A failing thermostat can call for the fan without calling for heat, or misread the room temperature.
- Overheating safety shutdown. A dirty filter or blocked airflow can trip the furnace’s safety limit, shutting the burner off while the fan keeps running to cool things down.
- Gas supply problem. If the gas to the furnace is off or interrupted, the burner can’t light. If other gas appliances in the house aren’t working either, call your gas company.
When to call
- The fan setting is on AUTO, the filter is clean, the registers are open — and the air is still cold.
- The furnace has locked out after repeated resets.
- The house is getting cold, or it’s below freezing outside. Don’t wait it out — call (616) 243-1914 or book a service call online. For after-hours help, see our emergency service page.
What a visit costs
A regular residential service call is $180. That covers diagnosis and repair under an hour, excluding parts. If a part is needed, we’ll tell you the cost before we install it. Emergency service is $285 for the first hour.
What not to do yourself
Checking the thermostat setting, the filter, and the registers is safe and easy. Do not open the furnace cabinet or work on gas or electrical parts inside the furnace. If the burner isn’t lighting or the furnace has locked out, that’s a professional repair — gas and electrical work inside a furnace is dangerous without training.
Related furnace problems
- Furnace Not Heating? No-Heat Furnace Repair in Grand Rapids, MI — if there’s no warm air at all
- Furnace Won’t Ignite? Ignition Failure Repair in Grand Rapids, MI — if the burner never lights
- Furnace Keeps Turning On and Off? Short Cycling & Intermittent Heat in Grand Rapids, MI — if the air goes warm, then cold, then warm again
- Furnace Repair in Grand Rapids, MI — our main furnace repair page
A-1 Heating & Air Conditioning — Grand Rapids, MI, serving Kent County since 1994. Call (616) 243-1914. We answer the phone 24 hours a day, 7 days a week. Regular service hours are Monday–Friday, 9 AM–5 PM. 24/7 emergency service is available.